Products
Products
-
Product Name:IPC-03 intelligent power monitoring unit
- Model: IPC-03
- Introduce:The IPC-03 Intelligent power monitoring unit is designed for station AC power supply system and low-voltage power distribution system. Its main fuction is to monitor and control the input switches, relay prection, Data detection and collection, Event recording, Feeder monitoring, real-time clock, etc. It consists of the monitoring module, display module, PLC control module, etc. It is highly integrated and has a outstanding performance.
- Description:
I. Main features1. Remote communication and controlThe IPC-03 has a standard RS485 communication port, which can be directly connected to the automatic integrated control system, realizing“four remote controls” on the up computer.The IPC-03 has a rocker switch on its panel for selecting local/remote control. When under local control, the user can set the working mode by using the function keys on panel. While under remote control, the user can remotely control or adjust the equipment on the up computer via RS485 communication. The remote control/adjustment commands will be performed after confirmation.2. Intelligent power control, with six working modes available Mode 1——Fixed power supply 1Mode 2——Fixed power supply 2Mode 3——Automatic power supply 3Mode 4——Automatic power supply 2Mode 5——Automatic changeoverMode 6——Power shutdown
ATS switch status display
3. Data detection and collectionThis device detects the inlet wire voltage, busbar voltage/current, frequency, active power, reactive power, active kilowatt-hour, reactive kilowatt-hour, and power factor in real time, and reports them to the upstream computer.It can detect undervoltage, overvoltage, and line breaks.4. Event recordingIt can accurately record alarms or actions in the following format: Year-Month-Day-Hour-Minute-Second-Millisecond, action value, action description.The event records are stored inside the equipment, which are not lost after power failure. Users can analyze the causes of the events by viewing the records. The upstream computer can invoke the SOE records at any time.The resolution of the SOE can reach up to 1ms.5. Protection functions(1) Abnormal voltage detection: It can analyze the voltage collected in real time and produce alarms for faults such as overvoltage, undervoltage, and loss of phase, and handle them according to the appropriate logics.(2) Busbar fault check: It determines whether the busbar fails by detecting the tripping of the switch.(3) Zero sequence overcurrent protection: This protection is provided to avoid the failure of the entire station due to high grounding. The zero sequence current is obtained by the dedicated zero sequence CT, which can eliminate the fault quickly and accurately to ensure the safety of the station power. This protection can be enabled/disabled, and so does the jump wire.(4) Overload protectionThe 03P is provided with quick break and overcurrent protection to solve the problem of mismatch between the feeder short-circuit tripping delay and the transformer station low-voltage switch tripping delay.6. Feeder status monitoringThrough the Boolean value input interface, users can monitor the running status of the feeder switch or such information as fault tripping, and handle the local audible/visual alarms.7. IPC-03H/N intelligent lighting fan load start/stop (new function)(1) Function overviewThe IPC-03H/N is an intelligent power monitoring unit designed to address the intelligent management needs of the lighting and fans of the transformer station. In addition to the functions mentioned above, the IPC-03H/N has the additional intelligent lighting/fan load start/stop function. By presetting the time for starting/stopping the load, users can exercise automatic control of the lighting facilities/fans. Also, users can modify the preset time on the remote computers or remotely control the lighting facilities/fans even when the set time is not due.(2) Features■Higher efficiency: Intelligent management for the start/stop of the lighting facilities/fans greatly reduces the work of the maintenance personnel;■Higher security: Remote control of the lighting facilities/fans is a more secure and efficient way of working;■Cost-effectiveness: It reduces the long-term maintenance cost by a minimum one-off investment.II. Type selectionModelApplicable mode6 working modesElectricity quality monitoring}Input/outputZero-sequence overcurrent protectionOverload protection}Touch screenRS485 communicationIntelligent lighting/fan start/stop}IPC-03A/LATS switch●●●●●●IPC-03A/HATS switch●●●●●●●IPC-03A/H/NATS switch●●●●●●●●IPC-03T/L3 switches●●●●●●IPC-03T/H3 switches●●●●●●●IPC-03T/H/N3 switches●●●●●●●●III. Specifications1. Normal operating conditions■Single-phase AC voltage: 220V±20%, AC voltage frequency: 50Hz±10%■Ambient temperature: -10ºC ~ +45ºC (operating), -25ºC ~ +55ºC (storage);■Daily average RH ≤ 95%, monthly average RH ≤ 90%;■The site should be free from conductive or explosive dusts, or gases or steams that may corrode or damage the insulation.2. Sampling accuracy of AC voltage/currentMeasurement accuracy: level 0.5 for IPC-03L, level 1.0 for IPC-03P3. Frequency sampling accuracy: ±0.01Hz4. Active kilowatt-hour: level 2.0, reactive kilowatt-hour: level 2.05. Boolean value input: high level (logic 1): DC 24V, low level (logic 0): DC 0V6. Egress relay contact point capacity: AC 250V/5A7. Chassis: standard 19-inch chassis8. Weight: <6Kg